A Multicenter Randomized Controlled Trial on the Effect of Low-intensity Pulsed Ultrasound on the Maturation of Newly Constructed Autogenous Arteriovenous Fistulas in Uremic Patients

Status: Recruiting
Location: See location...
Intervention Type: Device
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

This study aims to evaluate the effect of 12 week low-intensity pulse ultrasound (LIPUS) intervention on the maturation of newly constructed autologous arteriovenous fistulas in uremic patients. This study is a prospective, blinded, randomized controlled trial. This trial is divided into two stages. The first stage is a concept validation trial, which is a single center, prospective, blinded, randomized controlled clinical study. Subjects who meet the screening criteria are randomly divided into an intervention group and a control group in a 1:1 ratio. All subjects underwent safety and efficacy evaluations at the 2nd, 4th, 8th, 12th, and 4th week after treatment. After completing a 4-week follow-up of the 20th study subject, an analysis was conducted with the preset goal of achieving a higher maturation rate of arteriovenous fistula in the intervention group compared to the control group at the follow-up point, and the safety of the study was evaluated. The second stage is a key trial, which is a multicenter, prospective, blinded, randomized controlled clinical study. The inclusion criteria, primary and secondary endpoints, and safety endpoints of the study subjects remain unchanged, and the safety and efficacy of the overall population are evaluated.

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Maximum Age: 75
Healthy Volunteers: f
View:

• 18 years old ≤ Age ≤ 75 years old, regardless of gender or ethnicity;

• Dialysis or non-dialysis patients who have newly established autologous arteriovenous fistula in the wrist and have not yet used the fistula for hemodialysis treatment;

• Before establishing an autologous arteriovenous fistula in the wrist, ultrasound examination will be performed. The radial artery diameter at the intended surgical site is\>1.5mm, and the head vein diameter is\>2mm (using a tourniquet). The arterial and venous blood flow are unobstructed, and the distance between the vein and the skin is\<6mm;

⁃ 4\. After introducing dialysis, the calcium ion concentration in the dialysate will be maintained at 1.5mmol/L during the dialysis period, and low molecular weight heparin will be used for anticoagulation. The dosage of low molecular weight heparin remains unchanged (±1000U) during the study period;

⁃ 5\. Sign an informed consent form.

Locations
Other Locations
China
The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital
RECRUITING
Suzhou
Contact Information
Primary
Qiang Chen
chenqjs@126.com
+8618901547679
Time Frame
Start Date: 2024-02-26
Estimated Completion Date: 2026-12-31
Participants
Target number of participants: 300
Treatments
Experimental: LIPUS intervention group
Low intensity pulse ultrasound (LIPUS) intervenes at the anastomotic site, and if the ultrasound examination indicates the presence of a narrow site in the outflow tract, it also intervenes at the narrow site. It belongs to non-invasive extracorporeal intervention, with three times a week (during dialysis) for 20 minutes each time. The sound intensity is 350mW/cm2, the pulse frequency is 1MHz, the pulse repetition frequency is 100Hz, the pulse frequency is 100 times, and the treatment period is 12 weeks.
No_intervention: Simulated LIPUS control group
Using the same forearm wearable portable ultrasound as the LIPUS arteriovenous fistula intervention group, but not issuing low-intensity pulse ultrasound.
Related Therapeutic Areas
Sponsors
Leads: Suzhou Municipal Hospital
Collaborators: The First Affiliated Hospital of Soochow University, Dushu Lake Hospital Affiliated to Soochow University, The First Affiliated Hospital with Nanjing Medical University, Second Affiliated Hospital of Soochow University

This content was sourced from clinicaltrials.gov