Andre Autefage
Toulouse, France
Last Updated: 09/26/2026
Save publications for later
Sign Up
Not sure about your diagnosis?
Check Your Symptoms
Found 18 publications
Effect of tightening locking screws torque on unscrewing ability and on the screw removal torque.
Journal: Research in veterinary science
Published: September 07, 2025
Impacts of tibial plateau levelling osteotomy on the tibial insertion of the medial collateral ligament of the canine stifle joint - A cadaveric study.
Journal: Research in veterinary science
Published: May 01, 2022
Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model.
Journal: Veterinary and comparative orthopaedics and traumatology : V.C.O.T
Published: March 10, 2022
Morphometric assessment of the medial collateral ligament of the canine stifle joint.
Journal: Research in veterinary science
Published: September 06, 2021
Biomechanical Comparison of Two Locking Plate Constructs Under Cyclic Loading in Four-Point Bending in a Fracture Gap Model: Two Screws versus Three Screws Per Fragment.
Journal: Veterinary and comparative orthopaedics and traumatology : V.C.O.T
Published: January 16, 2019
Arthroscopic Management of Osteochondrosis of the Glenoid Cavity in a Dog.
Journal: Journal of the American Animal Hospital Association
Published: July 25, 2018
Plasma-Mediated Bipolar Radiofrequency Ablation of Overlong Soft Palate in the Dog: A Pilot Study.
Journal: Journal of the American Animal Hospital Association
Published: July 25, 2018
Effect of Tibial Plateau Levelling Osteotomy on Cranial Tibial Subluxation in the Feline Cranial Cruciate Deficient Stifle Joint: An Ex Vivo Experimental Study.
Journal: Veterinary and comparative orthopaedics and traumatology : V.C.O.T
Published: June 12, 2018
Effect of tibial tuberosity advancement on cranial tibial subluxation in the feline cranial cruciate deficient stifle joint: An ex vivo experimental study.
Journal: Research in veterinary science
Published: February 03, 2016
Biomechanical comparison of two locking plate constructs under cyclic torsional loading in a fracture gap model. Two screws versus three screws per fragment.
Journal: Veterinary and comparative orthopaedics and traumatology : V.C.O.T
Published: December 08, 2014
Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model.
Journal: Veterinary and comparative orthopaedics and traumatology : V.C.O.T
Published: July 08, 2013
Last Updated: 09/26/2026