Novel DBS Stimulation Patterns for Treatment of Parkinson's Disease - UNMC/Medtronic Collaborative Acute Feasibility Pilot

Status: Recruiting
Location: See location...
Intervention Type: Device
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

This is an open-label, non-randomized, proof-of-concept comparison of clinical vs. research stimulation patterns in patients with Parkinson's disease (PD) being treated with Deep Brain Stimulation (DBS) through the Medtronic Percept PC DBS device. The investigators hypothesize that stimulation patterns designed to better target excessive synchrony in a patient-tailored manner may result in more efficient and effective therapy with fewer side effects. Medtronic 3rd-generation sensing implantable neural stimulator, Percept PC, is FDA-approved for treating PD. The Percept PC device features BrainSense, the first and only available sensing technology for deep brain stimulation. BrainSense technology allows the device to capture and record brain signals (local field potentials, or LFP) using the brain-implanted DBS lead, while simultaneously delivering therapeutic stimulation. Investigators plan to enroll and complete investigations in 15 study subjects total, who have been previously implanted with the Medtronic Percept PC for the treatment of PD, and who are optimized for clinical stimulation and anti-Parkinsons medication. Investigations will be performed in UNMC Movement Disorders Clinic, UNMC Neurosurgery Lab, and UNO Biomechanics Research Building, Gait Lab. Subjects will receive research stimulation patterns and the effect on PD motor symptoms will be assessed via Unified Parkinsons Disease Rating Scale (UPDRS)-part III and gait measures. Videotaping of patient UPDRS-III testing and gait will be obtained.

Eligibility
Participation Requirements
Sex: All
Minimum Age: 19
Maximum Age: 80
Healthy Volunteers: t
View:

• Patients with idiopathic Parkinson's Disease who were recommended for STN DBS using standard clinical inclusion and exclusion criteria (e.g., presence of coagulopathy, dementia, untreated depression, pre-existing implanted stimulation system, prior intracranial surgery, history of alcohol or drug abuse)

• Patients have been previously implanted with bilateral STN DBS and the Medtronic Percept PC implantable neural stimulator.

• Patients are optimized for clinical stimulation and medication for at least 3 months post-surgery for the implantation of their DBS system.

• Consent to study participation

• Presence of a robust beta peak (detectable using the Percept BrainSense Survey feature; ≥ 0.7 µV/rtHz), intra-operatively (assessed via Lead Confirm technology from Alpha Omega)

• Good response to stimulation (30% improvement on UPDRS III compared to baseline OFF), at least 3 months post-surgery.

Locations
United States
Nebraska
Unversity of Nebraska Medical Center
RECRUITING
Omaha
Contact Information
Primary
Dulce Maroni, PhD
dmaroni@unmc.edu
402-215-3053
Backup
Jonathan Nguyen
jon.nguyen@unmc.edu
402-836-9407
Time Frame
Start Date: 2021-05-10
Estimated Completion Date: 2026-04
Participants
Target number of participants: 10
Treatments
Experimental: PD with DBS
Patients with Parkinson's Disease who were implanted with Medtronic Percept PC for DBS and consent to participate in the study.
Sponsors
Leads: University of Nebraska

This content was sourced from clinicaltrials.gov