Monocentric Randomised Controlled Trial Comparing Dual-mobility Cups Versus Unipolar Cups for Unselected Primary Total Hip Arthroplasty by Direct Anterior Approach

Status: Recruiting
Location: See location...
Intervention Type: Procedure
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

THA comprises the replacement of the damaged bone and cartilage with prosthetic components. The proximal end of the femur is replaced with a stem and ball/head, while the acetabulum is most commonly replaced with a unipolar cup (UP) that consists of a liner inside of a metal shell. UP cups are associated with risks of dislocations, especially in elderly and female patients, as well as in patients with lumbar stiffness or operated for femoral neck fractures. In fact, one of the most common reasons for early revision of UP cups are dislocations. Dual-mobility (DM) cups were introduced in the 1970s by the French surgeon Gilles Bousquet, as an alternative to UP cups. They are made up of two articulations, a femoral head moving inside a mobile polyethylene liner, which in turn moves inside a metal shell. This design allows for a greater jump distance and range of motion (ROM) compared to UP cups, thus resulting in reduced rates of dislocation. A recent systematic review that evaluated 5 case-control studies (549 DM cups vs 649 UP cups) and 3 registry studies (5935 DM cups vs 217362 UP) found that in case-control studies, the dislocation rates were 0.2% for DM cups versus 7.1% for UP cups (p=0.009). Furthermore, in registry studies the revision rates due to dislocation were 0.2% for DM cups versus 0.5% for UP cups (p=0.050). Nonetheless, there have been some concerns associated with the use of DM cups, including intra-prosthetic dislocations (IPD), polyethylene wear, and iliopsoas impingement. Since the early 2000s, new improvements in the design of DM cups have nearly eliminated the risk of IPD, and the use of ultra-high molecular weight polyethylene (UHMWPE) has greatly reduced wear rates, even in young and active patients. Lastly, although some studies have reported iliopsoas impingement with DM cups, the impingement is usually against the optional fixations, and not against the mobile polyethylene insert. The hypothesis of the present interventional randomised controlled trial (RCT) is that THA using DM cups will not provide inferior outcomes compared to THA using UP cups, in terms of hip awareness measured using the forgotten joint score (FJS).

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Healthy Volunteers: f
View:

• men and women aged ≥18 years old

• set to undergo elective primary THA via direct anterior approach (DAA)

• affiliated with a social security scheme

• able to answer questionnaires and to communicate freely in French

• who have been informed and have provided free, informed, and written consent (no later than the day of inclusion and before any examination required by the study)

Locations
Other Locations
France
Polyclinique Jean Villar
RECRUITING
Bruges
Contact Information
Primary
Nicolas Verdier
dr.nicolas.verdier@gmail.com
+33(0)535549569
Backup
Charlène Py
charlene.py@elsan.care
+33(0)556003048
Time Frame
Start Date: 2026-07-07
Estimated Completion Date: 2030-07-01
Participants
Target number of participants: 300
Treatments
Active_comparator: THA with dual-mobility cup
The THA will be performed via the DAA. The liner will be made of highly-crosslinked vitamin-E infused polyethylene. The femoral head will be made of either metal or ceramic. The dual-mobility cup will always be cementless, while the stem will be cemented in female patients aged ≥75 years, as well as in any patient diagnosed with osteoporosis. A blunt dissection will be carried out through the tensor fasciae latae muscle (TFLM), between the sartorius and rectus femoris muscles. A femoral neck osteotomy will then be performed using an oscillating saw, and the femoral head will be removed with a corkscrew. The acetabular components and the selected liner according to the randomisation, will then be implanted.The femoral head will then be impacted onto the femoral stem, and the prosthesis will be reduced. Closure of the surgical site will be performed in layers.
Active_comparator: THA with unipolar cup
The THA will be performed via the DAA. The liner will be made of highly-crosslinked vitamin-E infused polyethylene. The femoral head will be made of either metal or ceramic. The unipolar cup will always be cementless, while the stem will be cemented in female patients aged ≥75 years, as well as in any patient diagnosed with osteoporosis. A blunt dissection will be carried out through the tensor fasciae latae muscle (TFLM), between the sartorius and rectus femoris muscles. A femoral neck osteotomy will then be performed using an oscillating saw, and the femoral head will be removed with a corkscrew. The acetabular components and the selected liner according to the randomisation, will then be implanted.The femoral head will then be impacted onto the femoral stem, and the prosthesis will be reduced. Closure of the surgical site will be performed in layers.