Aortic Dissection Clinical Trials

Find Aortic Dissection Clinical Trials Near You

A Prospective, Multicenter, Randomized Controlled Study to Evaluate the Safety and Efficacy of the WeFlow-EndoSeal™ Aorta Vascular Plug System Combined With TEVAR for the Treatment of Stanford Type B Aortic Dissection

Status: Recruiting
Location: See location...
Intervention Type: Device, Procedure
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are: Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks. Participants will: Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Maximum Age: 80
Healthy Volunteers: f
View:

• Patients aged 18 to 80 years old.

• Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.

• Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..

• Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.

• Patients are able to understand the purpose of the trial, participate in this study voluntarily, has signed the informed consent form personally or via their legal representative, and is willing to complete follow-up in accordance with the protocol requirements.

Locations
Other Locations
China
First Medical Center of The Chinese PLA General Hospital
RECRUITING
Beijing
Contact Information
Primary
Huang Jin Jing
jingjing.huang@endonom.com
13916287877
Time Frame
Start Date: 2026-06-01
Estimated Completion Date: 2032-03-01
Participants
Target number of participants: 256
Treatments
Experimental: test group
The test group will be treated with the WeFlow-EndoSeal™ Aorta Vascular Plug System developed and produced by Hangzhou Endonom Medtech Co., Ltd. combined with TEVAR for patients with Stanford Type B aortic dissection
Active_comparator: control group
The control group will receive conventional TEVAR treatment in accordance with guidelines and expert consensus.