To Explore the Influence of Different Anesthesia Induction Schemes on the Quality and Clinical Effect of Electroconvulsive Convulsions in Patients With Depression Based on EEG Monitoring

Status: Recruiting
Location: See location...
Intervention Type: Other
Study Type: Interventional
Study Phase: Not Applicable
SUMMARY

Depression is a common clinical mental disease with high incidence rate, high recurrence rate, high suicide rate and high disability rate. As a first-line treatment for depression with refractory, high suicide risk and obvious psychotic symptoms, electric shock has a definite effect on depression, but may lead to cognitive impairment. The induction of extensive epileptiform discharges in the cerebral cortex by electric shock therapy is the key to ensure the treatment effect. The level of epileptiform discharges in the brain is mainly reflected in the quality of convulsions. The quality of electroconvulsive convulsions is affected by factors such as age, stimulation power, anesthetic drugs and depth of anesthesia. Most anesthetics have anticonvulsive properties, such as barbiturate or propofol, which may have a negative impact on the quality of convulsions, thus affecting the therapeutic effect. If the parameters of electric shock, such as stimulation dose, are modified, although the quality and treatment effect of convulsions can be improved, it may also lead to higher cognitive side effects. The depth of anesthesia also affects the quality and efficacy of electric shock convulsions, and the quality of convulsions is higher when stimulated at a shallow level of anesthesia. However, if the use of narcotic drugs is reduced to improve the quality of convulsions, the risk of restlessness and delirium after electric shock may be higher and the comfort of patients may be lower. Therefore, this study compared the effects of different anesthesia induction schemes on the quality and clinical efficacy of electroconvulsive seizures in patients with depression based on EEG monitoring, and explored the optimal depth of anesthesia.

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Maximum Age: 60
Healthy Volunteers: f
View:

• In-patients who meet the diagnostic criteria of moderate and severe depression in the 11th edition of the International Classification of Diseases (ICD-11)

• Age 18-60 years old, gender unlimited

• Primary school or above education level

• Indications for MECT treatment

• Normal hearing and vision (including color discrimination)

• The patient voluntarily participated in the study and signed the informed consent form, and the guardian also signed the informed consent form.

Locations
Other Locations
China
The First Affiliated Hospital of Chongqing Medical University
RECRUITING
Chongqing
Contact Information
Primary
Zhao B shu, MM
bangshuzhao@163.com
+8615823079815
Time Frame
Start Date: 2023-06-12
Estimated Completion Date: 2024-08-31
Participants
Target number of participants: 24
Treatments
Active_comparator: Group H:IoC1 60-70
This study used an EEG bispectral index monitor (Apolo 9000A) to monitor consciousness index 1 (IoC1) and consciousness index 2 (IoC2) before electric shock, and then induced anesthesia with propofol 1.5mg/kg and succinylcholine 1mg/kg, following by mask pressurized oxygen supply,dental pads protect the tongue and monitoring the concentration of end-expiratory carbon dioxide. Electrical stimulation is performed when the consciousness index 1 is between 60 and 70. The electrode is located on the bilateral temporal side;Electric shock equipment:ThymatronSystem Ⅳ Electroconvulsive System,manufacturer:SOMATICS, USA;Propofol manufacturer: AstraZeneca of the UK, concentration: 10mg/ml. Succinylcholine manufacturer: Shanghai Xudong Haipu Pharmaceutical Co., Ltd.China, concentration: 2ml: 0.1g.
Active_comparator: Group M: IoC1 50-60
This study used an EEG bispectral index monitor (Apolo 9000A) to monitor consciousness index 1 (IoC1) and consciousness index 2 (IoC2) before electric shock, and then induced anesthesia with propofol 1.5mg/kg and succinylcholine 1mg/kg, following by mask pressurized oxygen supply,dental pads protect the tongue and monitoring the concentration of end-expiratory carbon dioxide. Electrical stimulation is performed when the consciousness index 1 is between 50 and 60. The electrode is located on the bilateral temporal side;Electric shock equipment:ThymatronSystem Ⅳ Electroconvulsive System,manufacturer:SOMATICS, USA;Propofol manufacturer: AstraZeneca of the UK, concentration: 10mg/ml. Succinylcholine manufacturer: Shanghai Xudong Haipu Pharmaceutical Co., Ltd.China, concentration: 2ml: 0.1g.
Active_comparator: Group L:IoC1 40-50
This study used an EEG bispectral index monitor (Apolo 9000A) to monitor consciousness index 1 (IoC1) and consciousness index 2 (IoC2) before electric shock, and then induced anesthesia with propofol 1.5mg/kg and succinylcholine 1mg/kg, following by mask pressurized oxygen supply,dental pads protect the tongue and monitoring the concentration of end-expiratory carbon dioxide. Electrical stimulation is performed when the consciousness index 1 is between 40 and 50. The electrode is located on the bilateral temporal side;Electric shock equipment:ThymatronSystem Ⅳ Electroconvulsive System,manufacturer:SOMATICS, USA;Propofol manufacturer: AstraZeneca of the UK, concentration: 10mg/ml. Succinylcholine manufacturer: Shanghai Xudong Haipu Pharmaceutical Co., Ltd.China, concentration: 2ml: 0.1g.
Sponsors
Leads: Min Su

This content was sourced from clinicaltrials.gov