SUMMARY

The purpose of this study is to investigate the outcome of patients with pathologies of the ascending thoracic aorta (diseases in the great blood vessel or artery that leads away from the heart) including type A aortic dissection, retrograde type A aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm who are suitable for endovascular (within the vessel) repair with the Medtronic Valiant PS-IDE (Physician Sponsored-Investigational Device Exemption) Stent Graft. Type A aortic dissection is a condition where blood passes through the inner lining or between the layers of the blood vessel from a tear in the aortic wall (dissection) in the ascending aorta; a retrograde Type A aortic dissection is a condition where the dissection or tear in the ascending aorta starts from the descending aorta; an intramural hematoma is a collection of clotted blood within the aortic wall; a penetrating ulcer has a plaque or clot within the wall and a pseudoaneurysm is a false aneurysm . If left untreated in any of these conditions, the aorta can enlarge and rupture causing injury or death. The plan for these patients is to repair the ascending thoracic aorta using the Medtronic Valiant PS-IDE Stent Graft with the Captivia Delivery System. The Valiant Captivia has been evaluated worldwide and used extensively in patients with type B (descending) thoracic aortic dissection. Since the dissections in the ascending aortas mirror that of the descending aorta, it is expected that this stent graft will deliver similar performance and endurance in patients with type A aortic dissection. The investigators expect to reroute the blood to the true lumen (the inner space within the blood vessel) by covering the proximal (nearest to the heart) tear with the stent graft. The stent graft is a stent frame made from Nitinol wire and covered with an expandable material made of a polyester material. This new study will determine how well the device works to treat dissections, intramural hematomas, penetrating ulcers and pseudoaneurysms in the ascending thoracic aorta.

Eligibility
Participation Requirements
Sex: All
Minimum Age: 18
Healthy Volunteers: f
View:

• Patient must have a Type A thoracic aortic dissection, retrograde Type A thoracic aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm of the ascending thoracic aorta affecting the area between the Sinus of Valsalva and the innominate artery orifice (with no involvement of the aortic valve) and be considered candidates for endovascular repair;

• Patient must also have at least one cm proximal and distal landing zones in the ascending aorta between 28-44 mm in diameter;

• The patient must be deemed high-risk surgical candidate according to the following established criteria: ASA (American Society of Anesthesiologists) class IV.

Locations
United States
California
Long Beach Memorial Medical Center
RECRUITING
Long Beach
Cedars Sinai Medical Center
TERMINATED
Los Angeles
LAC Harbor-UCLA Medical Center
RECRUITING
Torrance
Contact Information
Primary
Rodney A White, M.D.
rawhite@ucla.edu
310 222-2704
Backup
Ali Khoynezhad, M. D., PhD
ali.khoynezhad@cshs.org
310 423-3851
Time Frame
Start Date: 2013-11
Estimated Completion Date: 2033-12
Participants
Target number of participants: 20
Treatments
Experimental: Endovascular repair of ascending aorta
Endovascular repair with Valiant PS-IDE Stent Graft